Carrier 58HDX - Final Gas Piping Check; ELECTRICAL WIRING; Power Supply Wiring

Carrier 58HDX
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
your
local
gas
supplier,
then
refer
to
Table
6
for
required
pressure
change
and/or
orifice
change
for
high
altitudes.
Ge
.
For
operation
with
Propane
gas,
gas
orifices
MUST
be
changed
and
manifold
pressure
MUST
be
maintained
as
per
Table
7
.
Orifices
can
be
ordered
through
our
distribut-
or.
(See
Fig.
38).
High
Altitude
Input
Rate
=
Nameplate
Sea
Level
Input
Rate
x
(Multiplier)
[USA]
|
High
Altitude
Multiplier
Elevation
Natural
Gas
Propane
Gas
2001’
-
3000°
0.95 0.90
3001’
-
4000°
0.93 0.86
4001’
-
5000°
0.91
0.82
5001’
-
6000°
0.89
0.78
6001’
-
7000°
0.87
0.74
7001’
-
8000°
0.85 0.70
*
Based
on
mid-range
of
elevation.
High
Altitude
Air
Pressure
Switch
Altitudes
over
4,000’
(1219
M)
may
require
a
different
air
pressure
switch
than
the
one
installed
at
the
factory.
Check
parts
list
for
pressure
switch
and
consult
your
distributor
for
part
number
and
availability.
In
Canada,
provincial
codes
may
govern
installation
of
switch.
Check
with
governing
authorities.
Changing
Orifices
for
High
Altitude
ELECTRICAL
SHOCK,
FIRE
OR
EXPLOSION
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury,
death,
and/or
property
damage.
Turn
OFF
electric
power
(at
disconnect)
and
gas
supply
(at
manual
valve
in
gas
line)
when
installing
orifices.
Lockout
and
tag
with
appropriate
label.
Installation
of
orifices
requires
a
qualified
service
technician.
NOTE:
Main
bummer
orifices
can
be
changed
for
high
altitudes.
1.
Disconnect
gas
line
from
gas
valve.
.
Remove
manifold
from
furnace.
Ww
.
Remove
the
orifices
from
the
manifold
and
replace
them
with
properly
sized
orifices.
f
.
Tighten
orifices
so
it
is
seated
and
gas
tight.
(See
Fig.
38)
5.
Reinstall
manifold.
Ensure
burners
do
NOT
bind
on
new
orifices.
Natural
Gas
Input
Rating
Check
SEE
CHECKS
AND
ADJUSTMENTS,
Natural
Gas
Input
Rating
Check
in
this
manual.
Measure
from
face
of
orifice
U
to
the
back
side
of
the
manifold.
AQ7726
Fig.
38
-
Changing
Orifices
Final
Gas
Piping
Check
FIRE
OR
EXPLOSION
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury,
death,
and/or
property
damage.
Never
test
for
gas
leaks
with
an
open
flame.
Use
a
commercially
available
soap
solution
made
specifically
for
the
detection
of
leaks
to
check
all
connections.
A
fire
or
explosion
could
result
causing
property
damage,
personal
injury
and/or
loss
of
life.
1.
The
furnace
and
the
equipment
shut
off
valve
must
be
dis-
connected
from
the
gas
supply
piping
system
during
any
pressure
testing
of
that
system
at
test
pressures
in
excess
of
1/5"
PSIG.
Close
the
manual
shut-off
valve
before
testing
at
such
pressures.
2.
When
installation
is
complete,
test
all
pipe
connections
for
leaks
with
the
gas
pressure
less
than
!/2"
PSIG
to
the
gas
valve.
3.
The
furnace
must
be
isolated
from
the
gas
supply
system
by
closing
the
equipment
shut
off
valve
during
any
pres-
sure
testing
of
the
gas
supply
system
at
test
pressure
equal
to
or
less
than
!/2"
PSI
(3.5
kPa).
4.
Apply
a
commercial
soap
solution
to
all
joints
to
test
for
leaks.
Correct
any
leaks
indicated
by
bubbles.
5.
Correct
even
the
smallest
leak
at
once.
6.
Check
for
leaks
at
gas
valve
and
orifice
connections
to
the
burner
manifold
while
the
furnace
is
operating.
ELECTRICAL
WIRING
Power
Supply
Wiring
The
furnace
MUST
be
electrically
wired
and
grounded
in
accordance
with
local
codes,
or
in
the
absence
of
local
codes
with
the
latest
edition
of
The
National
Electric
Code,
ANSI
NFPA
70
and/or
The
Canadian
Electric
Code
CSA
C22.1.
The
power
supply
to
the
furnace
connections
must
be
between
104
VAC
and 127
VAC
during
furnace
operation
for
acceptable
performance.
Field
wiring
connections
must
be
made
inside
the
furnace
connection
box.
A
suitable
strain
relief
should
be
used
at
the
point
the
wires
exit
the
furnace
casing.
Copper
conductors
shall
be
used.
Line
voltage
wires
should
conform
to
temperature
limitation
of
63°
F
(35°
C)
rise
and
be
sized
for
the
unit
maximum
amps
stated
on
the
rating
plate.
Add
the
full
load
amps
for
potential
field-installed
accessories
such
as
electronic
air
cleaners
and
humidifiers
that
would
receive
power
from
the
furnace
control.
The
furnace
control
is
rated
for
a
maximum
of
1.0
amp
combined
for
EAC
and
HUM.
Consult
NEC
or
local
codes
for
proper
wire and
circuit
sizing.
NOTE:
Fumace
will
not
have
normal
operation
if
line
polarity
is
reversed.
Check
ALL
field
and control
connections
prior
to
operation.
Junction
Box
(J-
Box)
Relocation
The
J-box
is
installed
on
left
side
of
casing.
An
alternate
j-box
location
on
right
side
can
be
used.
1.
Remove
bag
containing
two
hole
plugs
and
two
self
tap-
ping
screws
from
loose
parts
bag
in
blower
compartment.
2.
Remove
two
screws
holding
J-Box
to
casing.
3.
Move
large
hole
plug
from
right
to
left
J-Box
location.
4.
Clip
wire
tie
holding
J-Box
wires.