5.
Move
J-Box
to
alternate
location
and
attach
using
two
self
tapping
screws
from
bag.
6.
Apply
two
hole
plugs
from
bag
at
left
J-Box
location.
Thermostat
Thermostat
location
has
an
important
effect
on
the
operation
of
the
unit.
Follow
instructions
included
with
thermostat
for
correct
mounting
and
wiring.
Low
voltage
connections
to
furnace
must
be
made
on
terminal
board
of
furnace
control.
Heat
anticipator
setting
will
need
to
be
measured
if
24VAC
humidifier
is
installed.
Measure
current
in
series
from
R
to
W
at
the
thermostat.
Be
sure
24VAC
humidifier
is
wired
up
to
control.
Allow
furnace
to
operate
for
2
minutes
before
recording
the
AC
amperage
reading.
Set
anticipator
on
thermostat
to
recorded
value.
Optional
Equipment
All
wiring
from
furnace
to
optional
equipment
MUST
conform
to
local
codes
or,
in
the
absence
of
local
codes
with
the
latest
edition
of
The
National
Electric
Code,
ANSI
NFPA
70
and/or
The
Canadian
Electric
Code
CSA
C22.1.
Install
wiring
in
accordance
with
manufacturer’s
instructions.
The
wiring
MUST
have
a
minimum
temperature
rating
of
105°
C.
Humidifier/Electronic
Air
Cleaner
The
furnace
is
wired
for
humidifier
and/or
electronic
air
cleaner
connection.
REDUCED
FURNACE
LIFE
HAZARD
Failure
to
follow
this
caution
may
result
in
reduced
furnace
life.
Do
NOT
exceed
115V/1.0
amp.
maximum
current
load
for
both
the
EAC
terminal
and
the
HUM
terminal
combined.
HUMIDIFIER
-
The
24V
HUM
is
energized
when
the
pressure
switch
closes
on
a
call
for
heat.
The
115V
HUM
(called
HUM
on
Control)
is
energized
when
the
inducer
is
energized.
ELECTRONIC
AIR
CLEANER
-
EAC
is
energized
when
there
is
a
blower
speed
call,
except
is
NOT
energized
when
blower
operates
in
the
hard-wired
continuous
fan
mode.
Furnace
Control
The
furnace
control
is
preset
at
the
factory
with
a
fixed
blower
ON
delay
of
30
seconds
in
the
heating
mode.
The
blower
OFF
timing
is
preset
at
140
seconds.
If
desired,
the
fan
OFF
delay
can
be
reset
to
obtain
the
longest
delay times
while
still
maintaining
comfort
levels.
See
“Furnace
Wiring
Diagram”
.
NOTE:
Junction
Box
can
be
mounted
to
either
the
left
or
right
side.
115V.
60
Hz
S\2
oe
||
W
CORK
*.
‘8
Models
may
Connection
have
1
or
2
_—_
Box
pressure
switches
Ground
|
LowVoltage
'
Terminal
Board
NOTE:
115
VAC/60Hz/single-
phase
Operating
voltage
range*:
127
VAC
max,
104
VAC
min.
*
Permissible
limits
of
voltage
at
which
unit
will
operate
satisfactorily
Representative
drawing
only,
some
models
may
vary
in
appearance.
A07726
Fig.
39
-
Electrical
Connections
Furnace
Control
Fuse
The
24V
circuit
contains
a
5-amp,
automotive-type
fuse
located
on
furnace
control.
(See
Fig. 40.)
Any
electrical
shorts
of
24V
wiring during
installation,
service,
or
maintenance
may
cause
fuse
to
blow.
If
fuse
replacement
is
required,
use
only
a
fuse
of
identical
size
(5
amp.)
Blower
Off
Delay
Jumper
Diagnostic
Light
115
VAC
~
HUM
“™
EAC
A07727
Fig. 40
-
Control
Board
DUCTWORK
AND
FILTER
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury
or
death.
Do
NOT
draw
return
air
from
inside
a
closet
or
utility
room
where
furnace
is
located.
Return
air
duct
MUST
be
sealed
to
furnace
casing.