Blower
Off
Delay
Jumper
SN
|
Diagnostic
Light
(
24
VAC
HUM
115
VAC
~~
HUM
A07733
Fig.
49
-
Control
Board
Control
Board
Diagnostic
Codes
OFF
=
24VAC
or
115VAC
is
off,
fuse
is
open
Heartbeat
=
Normal
operation
or
no
previous
Diagnostic
Code
ON
SOLID
=
Soft
Lockout
Furnace
Control
Error
(1
hr.
delay)
If
code
repeats
immediately
following
power
reset
then
replace
control
1
Flash
=
Not
used
2
Flashes
=
Pressure
switch(es)
closed
when
should
be
open
3
Flashes
=
Pressure
switch
open
when
should
be
closed
4
Flashes
=
Limit
or
roll-out
switch
open
(less
than
2
minutes)
5
Flashes
=
Flame
sensed
out
of
sequence
6
Flashes
=
Failure
to
ignite
or
flame
sense
lost
while
running
6+
1
Flashes
=
Soft
Lockout
Max
trials
for
ignition
reached
(3
hr
delay)
7
Flashes
=
Soft
Lockout
Limit
or
roll-out
switch
open
longer
than
two
minutes
(1
hr
delay)
(roll-out
switch requires
manual
reset)
8
Flashes
=
Permanent
Lockout
Gas
valve
relay
contact
stuck
closed
or
miswired
gas
valve
(power
reset
only)
10
Flashes
=
Line
voltage
(115VAC)
polarity
reversed.
If
twinned,
refer
to
twinning
kit
instructions
*
If
status
code
recall
is
needed,
briefly
(2-3
seconds)
remove
then
reconnect
one
limit
switch
wire
(main
or
rollout)
to
display
last
stored
status
code.
Do
not
remove
power
or
blower
door
before
initiating
status
code
recall
or
code
will
be
lost.
Code
is
automatically
cleared
after
72
hours
or
upon
power
reset.
*
Proper
flame
sense
microamps:
0.7
microamps
D.C.
minimum,
2.0
4.0
microamps
nominal
Copyright
2010
Carrier
Corp.
*
7310
W.
Morris
St.
«
Indianapolis,
IN
46234
Printed
in
U.S.A.
Edition
Date:
10/10
Catalog
No:
58HDX-—02Si
Manufacturer
reserves
the
right
to
change,
at
any
time,
specifications
and
designs
without
notice
and
without
obligations.
Replaces:
583HDX-01S!
44

Other manuals for Carrier 58HDX

Related product manuals