62-11389 516
Table 52 Microprocessor Configurations - Continued
Configuration Selections Description
DISPLAY STANDBY RUN HR
YES / NO YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour
meter menu.
NO = This hour meter will not be displayed during
the startup messaging sequence. It will be dis-
played with the “other meters and counters”.
DISPLAY TOTAL SWITCH ON HR
YES / NO YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour
meter menu.
NO = This hour meter will not be displayed during
the startup messaging sequence. It will be dis-
played with the “other meters and counters”.
DIESEL RESET VALUE
(Refer to Table 81 for oil/filter
change intervals.)
0FF
50 TO 30,000
hours in 50 hour in-
crements
When the engine maintenance hour meter is reset,
the value selected here will be added to the to the
present meter reading to indicate to the micropro-
cessor when the next service interval alarm will be
activated. If the value entered is “0” the alarm fea-
ture is turned off.
STANDBY RESET VALUE
0FF
50 TO 30,000
hours in 50 hour in-
crements
When the standby maintenance hour meter is reset,
the value selected here will be added to the to the
present meter reading to indicate to the micropro-
cessor when the next service interval alarm will be
activated. If the value entered is “0” the alarm fea-
ture is turned off.
SWITCH ON RESET VALUE
0FF
50 TO 30,000
hours in 50 hour in-
crements
When the switch on maintenance hour meter is re-
set, the value selected here will be added to the to
the present meter reading to indicate to the micro-
processor when the next service interval alarm will
be activated. If the value entered is “0” the alarm
feature is turned off.
PM 1 - 5 (Preventative Maintenance
Hour Meters)
OFF
ENGINE
PROTECT
HOURS
SWITCH ON
PROTECT
HOURS
STANDBY HOURS
START CYCLES
HIGH SPEED
HOURS
COMPRESSOR
RUN HOURS
MAINTENANCE
DAYS
OFF = This selection will turn this meter OFF (will
not display).
ENGINE HOURS = this meter will count the engine
hours until the next reset interval.
SWITCH ON HOURS = this meter will count the
switch on hours until the next reset interval.
STANDBY HOURS = this meter will count the
standby hours until the next reset interval.
START CYCLES = this meter will count how many
times the engine has started until the next reset
interval.
HIGH SPEED HOURS = this meter will count the
number of hours the engine operated in high speed
until the next reset interval.
COMPRESSOR RUN HOURS = this meter will
count the number of hours the compressor has op-
erated until the next reset interval.
MAINTENANCE DAYS = this meter will count the
number of days until the next reset interval.