b. Generator Removal
1. Ensure the unit will not start automatically by dis-
abling any two way communication and placing the
Main Power switch in the OFF position. Disconnect
the high voltage source and lockout/tagout the re-
ceptacle.
2
2. Remove the nuts (2) from the exhaust connection.
3
4
3. Disconnect ground wire.
4. Cut the generator cables. (Leave the same length as
new generator wires.)
8
5
6
6
7
5. Unbolt snubber. Unplug the ENSCU.
6. Remove the locking plates from the rear engine
mounting bolts and then remove the engine frame
bolts (Leave front bolt on pump side loose.)
7. Place the engine support tool (P/N
86-04751-00.)
8. Unbolt battery cable clamps.
9
9. Remove fuel filter assembly. Unclamp hoses.

Table of Contents