Loading...
101 62-11389
SECTION 10
WIRING
10.1 HARNESS PLUG WIRING FOR UNITS WITH A MAIN POWER SWITCH LABELED ENGINE/OFF/
STANDBY
1MP - NATURAL
1
12
24
35
Component Terminal
REMSN1 (REMSN-E) 3 (14)
REMSN2 (REMSN-H) 4 (14)
CDP-3 5 (16) (30)
EVOP-3 (DP16-S) 6 (17) (30)
ENCT 7 (18)
CDT 9 (20)
CST 10 (19)
AAT 11 (22)
1RAT (DP16-H) 12 (23)
REMSN1 (REMSN-F) (SP1) 14 (3)
REMSN2 (REMSN-G) (SP1) 14 (4)
REMSN3 (REMSN-K) (SP1) 14 (33)
1MP - NATURAL (Continued)
Component Terminal
CSP-1 (SP16) 15 (29) (30)
OGF-OV (HC-1) (SP16) 15
CDP-1 16 (5) (30)
EVOP-1 (DP16-P) 17 (6) (30)
ENCT 18 (7)
CST (SP14) 19 (10)
EVOT (DP16-F) (SP14) 19 (32)
CDT 20 (9)
1DTT (DP16-B) 21 (34)
AAT 22 (11)
1SAT (DP16-D) (SP12) 23 (35)
1RAT (DP16-G) (SP12) 23 (12)
FLS-C 26
CSP-3 29 (15) (30)
CSP-2 (SP7) 30 (15) (29)
CDP-2 (SP7) 30 (5) (16)
EVOP-2 (SP7) (DP16-R) 30 (6) (17)
EVOT (DP16-E) 32 (19)
REMSN3 (REMSN-J) 33 (14)
1DTT (DP16-A) 34 (21)
1SAT (DP16-C) 35 (23)
Unused terminals: 1, 2,8,13, 24, 25, 27,28,31