62-11389
3−20
3.14 VIEW HOUR METERS
COOL DEFROST ALARM START‐STOP
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT CONTINUOUS
START‐STOP/
CONTINUOUS
TOTAL ENGINE HOURS: 0 HRS
1. Press the SELECT key until the MessageCenter dis-
plays “PRESS ↑↓ TO VIEW HOURMETERS”.
2. Press the green UP ARROW key. The MessageCenter will display “PRESS ↑↓ TO
SCROLL, THEN = TO LOCK” . Continue to press the green UP ARROW key to move
down the hour meter list, or press the DOWN ARROW key to move up the list.
5. The selected hour meter will remain in the MessageCenter for 10 seconds, then the
default message (“STATUS OK” or other customer specified message) will display.
6. To lock an hour meter in the MessageCenter for continuous viewing, press the = key.
The Data item will flash continuously to indicate it is locked.
7. Pressing any key on the keypad will unlock the item. Pressing the UP or
DOWN ARROW key will move to the next hour meter.
3. Displayed hour meters will depend on microprocessor configurations (refer to Table 5−2). Typical
displayed meters are: “TOTAL ENGINE HOURS”, “STANDBY RUN HOURS” and “TOTAL SWITCH
ON HOURS”.
4. Pressing the = key will access all other meters and display “OTHER
METERS AND COUNTERS”.
SETPOINT BOX TEMPERATURE
+34.5 F
-20.0
Hour meters available when “OTHER METERS AND COUNTERS” is chosen are:
Meters listed in Step 3 above and, up to 5 User
Configurable meters including:
Switch On Standby Hours
Engine Protect Hours.
Switch On Protect Hours.
Engine Sleep Hours.
Switch On Sleep Hours.
Compressor Run Hours
High Speed Hours.
Start cycles.