62-113894−7
FALLING
REFRIGERATED
COMPARTMENT
TEMPERATURE
SWITCH POINTS
-3.2F (-1.8C )
RISING
REFRIGERATED
COMPARTMENT
TEMPERATURE
SWITCH POINTS
Set point
-3.6F (-2.0C )
Pulldown = High Speed
6 Cylinder COOL
Low Speed
6 Cylinder
COOL
Set point
Low Speed HEAT
HTCON1
NULL
-1.4F (-0.8C)
-1.3F (-0.7C)
Switch Point = Controlling Temperature - Set Point
+ results are above set point, - results are below set point
Switch points are the same for Perishable Range and Frozen Range except
in Frozen Range heating is not allowed.
Enter cool at Start-Stop
Override Functional
Parameter Value
(+3.6 to 185F = +2 to 105C)
Enter high speed at
Start-Stop Override Func-
tional
Parameter Value + 2
(+7.2 to 23.45F = +4 to 125C)
Transition to low speed at
Start-Stop Override
Functional Parameter
Value + 1
(+5.4 to 19.85F = +3 to 115C)
Pull-Up = HEAT
HTCON1 & HTCON2
Figure 4−3 Continuous Operation Switch Points with Eco Mode set to YES