EasyManua.ls Logo

Carrier VECTOR 6500 - Speed Control System Diagnostics; Table 9−1 ENSCU LED Fault Chart

Carrier VECTOR 6500
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
98
62-11389
9.5 Speed Control System Diagnostics
Table 91 ENSCU LED Fault Chart
Fault LED flash code Diagnostic tree
1 Engine Over Speed: more than 2,530 RPM One Long–One Short Figure 91
2 No signal from ENSSN for 2 seconds after RPM
is greater than 1,000 RPM for 10 seconds, OR
for 5 seconds while engine cranking (no voltage
at ENSCU pin 18).
Two Long–One Short Figure 92
3 Fuel/speed actuator (FSA) wiring disconnected
or open circuit. Coil Resistance Spec: 2.8 ohm
+/- 10%.
Two Long–Three Short Figure 93
4 ENSCU supply voltage is greater than 26V. Two Long–Seven Short Figure 94

Table of Contents

Related product manuals