62-11389
62
MessageCenter MESSAGES - Continued
Message Description
CARD LOCKED - REMOVE CARD The lock switch on the PC Card is in the “Locked” position. To use
the PC Card, move the switch to the “Unlocked” position.
CARD REMOVED, DATA NOT COPIED The PC Card was removed before all data was copied onto the
card.
CARD REMOVED, REINSERT CARD The PC Card was removed from the card slot before the operation
was completed. Reinsert the PC Card into the card slot to perform
the operation.
CFG: =TO LOAD, TO CANCEL A Configuration Card has been inserted into the PC Card slot.
Press the = key to load configurations into microprocessor.
CHANGE INTELLISET TO EXIT The IntelliSleep IntelliSet is active. Alternates with “IN-
TELLI-SLEEP MODE” at 5 second interval whether unit is running
or not.
CHARGE MODE-HOLD=TO EXIT Service Mode has the refrigeration system set so that it can be
charged with refrigerant through the liquid line service valve. Press
the = key to manually exit, or wait until the charging is complete.
CHECK AT NEXT SERVICE INTERVAL The unit needs to be checked at next service interval.
There is currently an active non-shutdown alarm in the alarm list.
CHECK DOOR Door switch indicates that a refrigerated compartment door is not
closed.
CHECK FUEL LEVEL
(Requires Optional Sensor)
The level in the fuel tank is very close to empty.
CHK WIRES FROM MICRO TO KEYPAD There is a communication signal lost between the keypad, display
and control module. Check and test the wiring to the keypad/dis-
play
COMPONENT TEST MODE Pressing the = key while this message is being displayed will allow
user access to Component Test Mode.
CONFIG ERROR, REMOVE CARD There was an error configuring the microprocessor with the Config-
uration PC Card. Remove the PC Card from the slot.
CONFIGS COMPLETE,= TO EXIT The user has reached the end of the Configurations List. Pressing
the UP or DOWN ARROW key will start list over. Press the = key
to exit Configuration List.
CONFIGURATION MODE Press the = key to enter Configuration Mode.
CONFIGURATION NOT CHANGED New configuration selection was not entered (saved) within the 5
second time limit.
CONTINUOUS LOCKED The current set point is within a range that has been locked into the
Continuous Run Mode. Start-Stop can not be selected.
CONTINUOUS RUN MODE SELECTED The unit operating mode has been changed from Start-Stop to
Continuous Run.
COPY COMPLETE, REMOVE CARD XX A DownLoad PC Card has been inserted into the PC Card slot, and
all data from the DataLink data recorder has been copied onto the
PC Card. You may safely remove PC Card from the slot. XX =
number of empty download slots remaining on the card.
COPY ERROR, REMOVE CARD XX A DownLoad PC Card has been inserted into the PC Card slot and
an error occurred while the data was being copied onto the PC
Card. You may safely remove the PC Card from the slot.
XX indicates the number of empty download slots remaining on the
card.
COPYING DATA-PLEASE WAIT A DownLoad PC Card has been inserted into the PC Card slot and
all data from the DataLink data recorder is being copied onto the
PC Card. DO NOT REMOVE THE CARD WHILE THIS MESSAGE
IS BEING DISPLAYED.
DATA RECORDER FAILURE The microprocessor has stopped recording Unit Data.
DEFROST CYCLE STARTED The unit has gone into defrost.
DOOR OPEN A refrigerated compartment door is open.