62-11389
318
Table 3-1. Unit Data - Continued
* Displays information or setting entered in the microprocessor Configurations
+ May or may not be displayed depending on Parameter/Configuration settings
SUPPLY AIR TEMP Supply (air leaving evaporator) temperature
DELTA-T Supply air temperature minus return air temperature
AMBIENT AIR TEMP Ambient (air entering condenser) air temperature
DEFROST TERM TEMP 1 Defrost termination temperature
SUCTION LINE TEMP Suction line temperature at the compressor
EVAP OUTLET TEMP Suction line temperature leaving the evaporator outlet
COMP DISCHARGE TEMP Compressor discharge temperature
BATTERY Battery voltage
CURRENT DRAW (DC) Battery charging or discharging amps
ENGINE RPM Engine speed
UNIT AC CURRENT #1 High voltage current draw on circuit #1.
UNIT AC CURRENT #2 High voltage current draw on circuit #2.
+
FUEL LEVEL This is only displayed when the sensor is configured ON. % of fuel in
tank.
SUCTION MOD VALVE
% open of CSMV
EXPANSION VALVE
% open of EVXV
START MODE AUTO if the engine will start automatically
MANUAL if the engine must be started manually
+
INSTALLED OPTIONS This is only displayed when one or more options is configured ON. Lists
installed options. Press “=” to access the list.
SOFTWARE REVISION Revision of the software that is operating the microprocessor
DISPLAY SOFTWARE REV Revision of the software that is operating the display
CONTROL SERIAL # Serial Number of the microprocessor
*
TRAILER ID # ID (as configured by the user)
*
UNIT SERIAL # Unit serial number
*
UNIT MODEL # Unit model number
+
HOURS TO ENGINE
MAINTENANCE
This is only displayed when the meter is configured ON. Number of en-
gine hours until the next programmed engine maintenance
+
HOURS TO S/B MOTOR
MAINTENANCE
This is only displayed when the meter is configured ON.
Number of hours until the next programmed electric standby motor main-
tenance.
+
HOURS TO UNIT
MAINTENANCE
This is only displayed when the meter is configured ON. Number of
switch-on hours until the next programmed general unit maintenance.
+
TIME LEFT TO PM (1-5) This is only displayed when one or more of the meters is configured ON.
Number of hours until the next programmed maintenance. (May display
user programmed identification.)