1
Installation & Connection
1) Load cell connection
Connect load cell connector to load cell port which is in the backside of the indicator.
* Connecting method
Pin #
Pin Function Color
1 EXC+ Red
2 SEN+ Brown
3 EXC- White
4 SEN- Black
5 SIG+ Green
6 SIG- Blue
7 SHIELD External
Note 1. When using the 4-wired type Load Cell,
Connect EXC+ and SEN+ to "EXC+" terminal (LoadCell Input + terminal) to use
Connect EXC- and SEN- to "EXC-" terminal (LoadCell Input - terminal) to use
Note 2. The color of the connectors may be different depending on the model and/or
the Load Cell manufacturer
Note 3. A maximum number of 8 similar loadcells may be used. (Reference: 350Ω)
Note 4. The calculated value of 1 division may not be set based on resolution and/or capacity.