4
Communication & Print Function
F20
Function Set the Device ID (Device ID)
Display Signification
F20. 01 Device ID 01
Set-up Range
(00 ~ 99)
F20. 99 Device ID 99
Not 1. This function can be used as custom ID for the Indicator in Command Mode.
F21
Function Set the Parity Bit (Parity Bit – RS-232C & PRT)
Display Signification
F21. 0 Data Bit 8, Stop Bit 1, Parity Bit: None
F21. 1 Data Bit 7, Stop Bit 1, Parity Bit: even number
Set-up Range
(0 ~ 2)
F21. 2 Data bit 7, Stop Bit 1, Parity Bit: odd number
Note 1. F21, F22, F23 are equally applicable in 2 serial communications (RS-232C, PRT)
F22
Function Set the Communication Data
Display Signification
F22. 0 Transmit displayed value
F22. 1 Transmit gross weight
Set-up Range
(0 ~ 2)
F22. 2 Transmit net weight