<Checker Mode 1> Relay Operation Graph when #5 of F51 is Set.
Weight
Above Step 4
Step4
ST
Step3
Step2
Step1
Near Zero
Near Zero ≤ Step1(SP1) Output 1
Step1(SP1)≤ Step2(SP2) Output 2
Step2(SP2)≤ Step3(SP3) Output 3
Step3(SP3) ≤ Step4(SP4) Output 4
Above Step4(SP4) Output 5
Near Zero 6 Output 6
Note.
1. Required set value input: Step4> Step3) > Step2) > Step1
2. Near zero output is according to the specified range in F57.
3. T3: Refer to F54 (Delay time of judgment-relay output)
T4: Refer to F55 (Operation time of judgment-relay output)
4. Relay Output
SP1: Near Zero < Stable Weight ≤Step1
SP2: Step1< Stable Weight ≤ Step2
SP3: Step2< Stable Weight ≤ Step3
SP4: Step3< Stable Weight ≤ Step4
Above SP4: Stable Weight ≤Above Step4
Near Zero: F57 Set Value ≥ 0 range output
5. SP 1-4‘s status lamps in the front panel are operated in the same manner as the RELAY output.
T3 T4
T3 T4
T3 T4
T3 T4
T3 T4