62
F57
Function Set-up for the Near Zero Range (NEAR ZERO(EMPTY))
Display Signification
F05. 0 Operation of near zero when weight indicated is 0
F05. 2
Operation of near zero when weight indicated is under
2 divisions
Set-up Range
(0 ~ 99)
F05. 9
Operation of near zero when weight indicated is under
9 divisions
Note 1. Relay is activated when no weight is detected.
Additional Set-up Functions
F60
Function Set the Forced Zero Range
Display Signification
Set-up Range
(00 ~ 99)
00
F60 ~
99
A function when weight is indicated below the set value and
when it’s stabilized, its value is indicated as “O.”
Note 1. If you select this function, you can automatically perform zero compensation (before re-weighing) when it is
under the set value without using
Zero key.
Ex) On a scale with the maximum indicated weight set as 120.00 kg, the division unit
value set as 0.02 kg, and F60 set as 30, when the stable LED turns ON with a
mass that is up to ±(0.02∼0.30kg), then zero compensation will automatically occur
and the indicated value will be “0.00 kg.”
F61
Function Set the Hold OFF time
Display Signification
Set-up Range
(00 ~ 99)
0.0
F61 ~
9.9
Set the Hold OFF time from 0.0 sec ~ 9.9 sec.
F62
Function Designate the Code Number
Display Signification
F62 0 Fixed
F62 1 After 1 weighing operation, increase by 1
Set-up Range
(0 ~ 2)
F62 2 After 1 weighing operation, decrease by 1