EasyManua.ls Logo

CAS CL-3000 Series - 2.7.6 Scanner; 2.7.6.1 New;Edit Scanner Conversion Table

CAS CL-3000 Series
225 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
103
1. Enter the number of Conversion
Table to be deleted
EX) Delete Conversion Table no. 2
Note: There is no confirmation request when deleting a Table No. Pressing the
PRINT key will cause the Conversion Table No. entered to be deleted.
2.7.6.3 Scanner Config (Menu code 1464)
( MENU 4. Store Data Table 6. Scanner 4. Scanner Config )
1. The way to set up Scan Form
Enter defined 13-digit number or
letter that scanner can recognize.
Assigned representative characters are
written below.
-“X” character : It must be the number of same digit length as “Mapping Code”, that you entered
above, has.
-“W” character : It represents weight date.
Any other symbol than “X”, “W” is ignored when scanning.
Example 1) Scan Form : [ XXXXXXXWWWWWC ]
- From 1 to 7 digits“XXXXXXX”calls PLU comparing with Mapping Code entered above 4).
- From 8 to 12 digets“WWWWW”shows the value of weigh.
Example 2) Scan Form : [ 00XXXXX000000 ]