21
Enter the number of samples which are removed and press the SAMPLE
key. The unit weight appears and negative counting is performed.
Release the reduction unit weight
Remove samples from the platter, press TARE and CLEAR keys.
E. Storing PLU(Product Look Up) to Memory
1) How to store unit weight in memory cells
Give a long press of MEMORY to enter into Memory mode, and obtain
unit weight by inputting the known value(ex. 35g) or by sampling operation
mentioned before. Press the ENTER key to confirm the value.
Note : Press the “MOVE” key to change the value when a wrong value
entered.
Keyed in the unit weight value.
If sample operation is done before entering this mode, unit weight window
will automatically show the unit weight.
Enter the tare value(ex. 10g) and press the ENTER key to confirm the value.