6
4
10. RS-232 Output
The scale can be ordered with as standard RS-232 output.
1. Mode E1A-RS 232C’s UART signal
2. Format :
Baud rate: 9600 BPS
Data bits: 8 BITS
Stop bit: 1 BIT
Code ASCll
Connector:9 Pin Socket
Pin2 Input
Pin3 Output
Pin5 Signal Ground
Data digit
specification
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1
st
row: Net weight-Data title space data unit CR
2
nd
row: Unit weight-data title space data unit CR
3
rd
row: Quantity-data title space data CR(14 15)
4
th
row: Tare weight-data title space data weight CR
4
th
row data. OA
NET=stable Net Weight net= unstable Net Weight
PCS=stable Quantity pcs= unstable Quantity
Tare=Tare Value U/W=Unit Weight
CR: OD OA Gross=Gross Value
Note : The new line demands “OA” will appear when the total data has been transmitted.