EasyManuals Logo

CAS EC-II Series User Manual

CAS EC-II Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
4
4
C. Change unit of measure from kg to pound
Keep pressing ENTER key in USER PROGRAMMING FUNCTION
MODE and release until the following displays appear.
Press MOVE key to revolve the system-preset units of measure (ON, OFF)
(Default setting : ON)
Press CLEAR key to determine and return to normal counting mode or press
ENTER key for determination and move to next.
Turn off the scale to return to normal counting mode.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAS EC-II Series and is the answer not in the manual?

CAS EC-II Series Specifications

General IconGeneral
BrandCAS
ModelEC-II Series
CategoryScales
LanguageEnglish

Related product manuals