P. Stable Class Range
Keep pressing ENTER key in USER PROGRAMMING FUNCTION
MODE and release until the following displays appear.
Press MOVE key to revolve the system-preset stable class range.
The smaller number selected, the shorter time for display stability
(0=off, 1=0.05d, 2=0.15d, 3=0.25d, 4=0.35d, 5=0.45d).
(Default setting : 1)
Press CLEAR key to determine and return to normal counting mode or press
ENTER key for determination and move to next.
Turn off the scale to return to normal counting mode.