25
Error
Meaning Action
Code
8-2. Fiscal ROM error code
Error code will be printed when the machine has the Fiscal ROM memory trouble.
Initialize or Flag clear operation is necessary.
Initialize or Flag clear operation is necessary.
Initialize or Flag clear operation is necessary.
Initialize or Flag clear operation is necessary after
repair the machine.
Connect the display PCB cable. Then, Initialize or
Flag clear operation is necessary. Even if the error
happens, it is necessary to repair the display PCB.
Initialize or Flag clear operation is necessary.
It is not possible to release this error.
Initialize or Flag clear operation is necessary.
Initialize or Flag clear operation is necessary.
Initialize or Flag clear operation is necessary.
It is not possible to release this error.
Initialize or Flag clear operation is necessary.
Initialize or Flag clear operation is necessary.
It is not possible to release this error.
It is not possible to release this error.
Initialize or Flag clear operation is necessary.
It is not possible to release this error.
Read after write error
Verify after write error
Read error
Hard error
Display PCB connection error
Z No. Fiscal last Z No.
GT over flow error
GT (ECR memory) GT (Fiscal ROM)
ID No. data error
GT data error
Fiscal ROM end
Fiscal ROM header data error
Fiscal ROM address line error
Temporary ID No. erase error
Blank check error
Fiscal ROM VAT data error
Fiscal ROM initialization time over error
Note: Even in case the error is not possible to release, the fiscal EP-ROM read
report can be issued by read operation after initialize or flag clear operation.
01
02
03
04
05
07
09
10
11
12
13
14,16
15,17
18
19
23,24
26