- 28 -
1. Structure
Conductor Material: Tin plated mild copper twist
Cross section area: 0.5mm
2
Construction: 20 pieces/0.18 mm
O.D. 0.95 mm
Insulation Material: Polyethylene
Thickness 0.3 mm
Sheath Material: PVC
Thickness 1.3 mm
Finished O.D.: 6.0 ~6.5 mm
Approx. weight: 55 kg/km
2. Properties (20°C)
Maximum conductor resistance 38.7 /km
Minimum insulation resistance 10 kM•km
Electric strength AC350 V/1 minute
Electrostatic capacity (Standard) 75 nF/km
To connect the In-line cable, release the 2 screws from the back cover.
Then, remove the Back cover. And, put the In-line connector to the ARCNET In-line port.
Do not foget to connect the shield wire (copper tape part) to the FG plate by the cable
supporter with screw.
Connect the In-line
cable shield wire to
FG plate.
In-line port
(ARCNET)
Release the 2 screws to remove
the bachk cover.
5) Specification of the In-line cable