Removing an IO link does not remove the device from the network, it simply
removes the I/O connection. The WiZo will still be a part of the network and continue
to work as a signal repeater, ensuring that the network is robust and remains fully
redundant.
Supervision mode is when the mesh network is in an error state due to a network
resource being lost. The user will notice that either the Input WiZo or the Output WiZo’s
right-handLink[I]or[O]buttonwillash.
The link may be lost due to:
• poor signal
• one or more WiZos have lost power
• A WiZo has been removed from the network
Start
1. Power down the WiZo to be removed.
2. Press and hold the I/O button, and power up the device.
3. The WiZoemitsarapidbeepsuccessionandthethreeLEDsashslowly.
4. Release the button.
5. Cycle power to the device. The device will power up in its default state.
Removing a device from the network follows the same process as a master reset.
[Net],[I]&[O]LEDsallashwhilethedevicereturnstofactorydefault.
Pre-step
1. Identify the device to be removed.
2. Ensure that there is no dependency on this device by other devices.
4.7. Supervision Mode
A WiZoboardcanbeusedasaNetworkErrornoticationsystem,ifitsoutputisnot
conguredandhasnoinboundlink.TheinputontheWiZocanbeconguredto,for
example, another WiZo, which controls a gate motor. If the WiZo controlling the gate
motor fails or is lost, the output on the input WiZo will automatically switch on when the
WiZogoesintoSupervisionmode.IfaG-ULTRAunitisconnected,thisnoticationcan
be used to communicate a network failure or error.
• Link[I]asheswhentheinputWiZo loses connection to an output WiZo
• Link[O]asheswhentheoutputWiZo loses connection to an input WiZo
QUICK START SECTIONSECTION 4