chapter 5000
page 79
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
MAIN MENU: PROGRAM VACC. (MASTER connection number 3)
Repeat the same operation selecting the backward direction.
This setting must be made with the parking brake released
Press ROLL until reaching the program VACC
These are the old parameters stored
Press ENTER
Reset of the parameters
Select the forward direction
Press the accelerator pedal slowly until the maximum stroke
Press OUT keeping the acc. pedal pressed
Press ENTER to confirm and release the pedal
Press ENTER
Press ENTER
MAIN MENU
PARAM. CHANGE
MAIN MENU
PROGRAM VACC
VACC SETTING
0.6 1.6
VACC SETTING
0.0 0.0
VACC SETTING
0.6 1.6
ARE YOU SURE?
YES=ENTER NO=OUT
DA2M2B C CE 1.13
48V 280A 00000