chapter 5000
page 99
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
Press ENTER
Press ENTER
MAIN MENU: PARAMETER CHANGE (PUMP connection number 5)
Scroll the parameters using ROLL and save the new values pressing OUT and then ENTER
MAIN MENU
PARAM. CHANGE
ACCELER/DELAY acceleration ramp.
DECELER/DELAY deceleration ramp.
MAX SPEED UP determines the maximum lifting speed controlled by a potentiometer.
MIN SPEED UP determines the minimum lifting speed controlled by a potentiometer when the
lift enabling switch is closed.
CUTBACK SPEED speed reduction when the cutback switch is active.
(+V =E4; input E13) if E13 is open the Cutbackspeed is on,
is the E13 is closed the Cutbackspeed is off.
CUTBACK SPEED 2 speed reduction when the cutback switch is active.
(+V =E4; input E14); if E14 is open the Cutbackspeed is off,
if E14 is closed the Cutbackspeed is on.
1ST SPEED FINE tilt speed, fine regulation.
2ND SPEED FINE side-shift speed, fine regulation.
3RD SPEED FINE 4th
th
lever speed, fine regulation.
4TH SPEED FINE 5th
th
lever speed, fine regulation.
AUX FUNCTION 1 pot. value increasing the motor RPM.
HYD SPEED FINE hydro speed, fine regulation.
MAXIMUM CURRENT maximum current of the inverter.
AUXILIARY TIME time delay when a hydraulic steering function request is switched off.
AC2P2B D CE 1.06
48V 350A 00000