EasyManua.ls Logo

CEStronics CES OMEGA FLEX - Page 65

CEStronics CES OMEGA FLEX
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Steps Signal
1. Hold the Program-Master in the reading field of the locking device for approx. 1 second.
‘Delete mode’ has been started. 1x short green
2. Now you can delete any number of locking media successively by holding each locking medium
in the reading field of the locking device for approx. 2 seconds.
The locking medium is deleted. 2x short green after each
locking medium
3. Hold the Program-Master in the reading field of the locking device for approx. 1 second.
‘Delete mode’ has been terminated. 1x long green
‘Delete mode’ is terminated automatically after approx. 5 seconds. The locking media
previously held up to the reading field are deleted from the locking device.
All master media that have been held in the reading field are now no longer authorised to open
this locking device.
Troubleshooting:
Signal Cause Solution
During step 1:
1x long red The Program-Master has not yet been authorised for
this locking device.
Authorise the Program-Master
During step 2:
2x short red The locking medium has not been authorised by the
Program-Master being used.
Use the Program-Master with
which the locking medium was
authorised.
1x short green The locking medium was held in the reading field of
the locking device for too short a time. The author-
isation has not been deleted.
Hold the locking medium in the
reading field of the locking device
for a longer time.
Wide shield replacement handle set ILS-I Page 65 of 83
11.5 Locking media
Overview: Use of master media
Help & troubleshooting
Technical data
Maintenance & disposal Operation Administration Assembly Basic information