The FLEX-AUGER Feed Delivery System requires minimum maintenance.
However, a routine periodic inspection of the equipment will prevent
unnecessary problems.
Maintenance should be done by a qualified technician.
ALWAYS DISCONNECT POWER TO THE SYSTEM WHEN
SERVICING OR MAINTAINING THE EQUIPMENT. FAILURE TO
DISCONNECT POWER MAY CAUSE INJURY OR DEATH.
1.Periodically check and tighten the delivery system hardware.
2.Grease boot bearings on grease fittings regularly, using an automotive or
industrial type grease.
3.Keep the FLEX-AUGER tubes level. Adjust if necessary. Wear increases at the points where tubes sag.
4.Replace the Plastic Shipping Plug in the power unit gear head with the Vented Plug during installation of the
Power Unit.
5.Check the oil level in the gear heads at installation and every 6 months. The Pipe Plug, on the side of the gear
head, indicates proper oil level. Add SAE 40W oil when necessary.
The oil in the gear heads should be replaced every 12 months with new SAE 40W oil.
A. Remove the bottom Pipe Plug to drain the oil. Discard used oil in accordance with local and national
codes.
B. Wipe any debris off the magnet on the bottom Pipe Plug and reinstall. Remove the side Pipe Plug and
(top) Vent Plug.
C. Set the power unit in the horizontal position.
D. 2-Stage Gear Heads: Add approximately 9 oz. (266 ml) of SAE 40W oil through top hole. This should
be just enough oil to reach the side Pipe Plug.
3-Stage Gear Heads (3261-9, 3261-12, 3261-14): Add approximately 13 oz. (384 ml) of SAE 40W oil
through top hole. This should be just enough oil to reach the side Pipe Plug.
E. Install the side Pipe Plug and (top) Vent Plug.
6.If the system is not to be used for an extended period of time, remove all the feed from the auger lines.
Disconnect power to the system to prevent accidentally starting the system.
7.If the system must be disassembled, extreme caution must be used
to prevent injury from springing auger.
A. Disconnect power to the entire system.
B. Pull the Anchor and Bearing Assembly and approximately
18” (45 cm) of auger out of the boot.
C. Place a clamp or locking pliers on the auger to prevent it
from springing back into the auger tubes.
D. Anchor and Bearing Assembly.
E. Carefully release the clamp securing the auger.
CAUTION: Stand clear...the auger will spring back into the tubes.
F. Remove the remaining system components in the opposite order they were installed, according to this
manual.
Maintenance

Table of Contents

Other manuals for Chore-Time FLEX-AUGER 108

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chore-Time FLEX-AUGER 108 and is the answer not in the manual?

Chore-Time FLEX-AUGER 108 Specifications

General IconGeneral
BrandChore-Time
ModelFLEX-AUGER 108
CategoryIndustrial Equipment
LanguageEnglish