EasyManua.ls Logo

Chore-Time Tronics 3 - Special Functions; Tunnel Fan Operation During Feeding

Chore-Time Tronics 3
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Special Functions Chore-Tronics® 3 Breeder Edition Control
38
MT2484A
Tunnel Fan at Feeding
Tunnel Fans at Feeding-If it is desired to have extra Tunnel Fans turn on during feeding, the settings are made
here. The number of Tunnel Fans to turn on, how long to keep them on after the feeding is over and whether or
not to Control the tunnel Fans by Temperature.
1.Put a Check in the "Use Tunnel Fans During Feeding" Box
When Feeding Begins:
2.Number of Tunnel Fans to Use.
3.Extra Runtime after feeding.
4.If in Power ventilation will pre-open Tunnel Doors to the users setting.
5.If using temp control, check the "Use Temperature Range During Feeding" box.
6.Degrees above set temperature to start turning extra Tunnel Fans back on.
7.Degrees below set temperature to start turning extra Tunnel Fans off (one at a time).
8.Time to wait after turning an extra Tunnel Fan on or off before checking the temperature again.
Special Functions
1
2
3
7
4
5
6
8