Description of Panel
4-7
<
M
E
M
M
A N A G E >
P L E A S E E N T E R
P A S S
W
O R D . . .
F2
F3
F4
F1
4.4 Operation Instruction
4.4.1 Operating the Measurement Setting
1. After turning the instrument on and ensuring every event is OK, then enter Rx parameter
test as the following menu.
<
M
E A S . D I S P L A Y >
*
D R I V E : P U L S E +
D R Y : O F F
T R I G . : I N T
N E X T P
A G E 1
4
Select test mode
F2
Select DRY CIRCUIT OFF or ON
F3
Select trigger mode
F1
R
x
:
1
9
Switch to next page (Now is page 1)
0
.
0
1
m
Ω
F4
<
M
E A S . D I S P L A Y >
*
R A N G E : A 2 0 0
m
Ω
S P E E D : F A S T
Z E R O : O F F
N E X T P A G E 2
4
Select range
F2
Select test speed
F3
Select zero function OFF or ON
F1
R
x
:
1
9
Switch to next page (Now is page 2)
0
.
0
1
m
Ω
F4
<
M
E A S . D I S P L A Y >
*
C O
M
P A R E : O F F
B I N N I N G : O F F
T E
M
P . : O F F
N E X T P A G E 3
4
F4
High, low limit compare setting
F2
Binning setting
F3
Switch to next page (Now is page 3)
0
1
m
Ω
F1
Temperature correction
measurement
setting
0
.
R
x
:
1
9
<
M
E A S . D I S P L A Y >
*
U N D C N A : O F F
N E X T P A G E 4
4
DC+ NA Mode Value OFF or ON
F2
F3
F4
Switch to page 1 (Now is page 4)
F1
R
x
:
1
9
0
.
0
1
m
Ω
Notices:
The 16502s panel displays the resistance value dividing into two kinds of RX and RTC.
Among these two, RX is only for measuring resistance value and it wont be affected by
the temperature measurement result. RTC represents the instrument being with the
functions of temperature measurement and correction, thus the display value of resistance