Descriptions of GPIB Interface (Commands Same as RS232 Interface)
5-7
(3) <NR3> format:
Ex.: 9.0E+3
<digit> <digit>
<digit>
+
-
.
+
-
E
5.3.3 Command Description
ABORt Command
Command: ABORt
Parameter: None
Return: None
Function: It aborts the measurement in executing immediately.
CALCulate Command Set
(1) Command: CALCulate: ALARm:CONDition { FAIL | PASS}
Function: It defines the alarm output.
Parameter: FAIL The alarm enables when the comparison result is FAIL.
PASS The alarm enables when the comparison result is PASS.
Return: The query returns FAIL or PASS.
(2) Command: CALCulate: ALARm:MODE { PULSe | CONTinuous }
Function: It sets or queries the beepers action in comparion function.
Parameter: PULSe It beeps with pulse.
CONTinuous It beeps continuously.
Return: The query returns PULS or CONT.
(3) Command: CALCulate:BINNing:CLEAr
Function: It clears STBY state of BIN test result.
Parameter: None
Return: None
(4) Command: CALCulate:BINNing:RESUlt?
Function: It returns BIN SORT result.
Parameter: None
Return: The query returns <NR1> +0~+9,+11,
+0 BINNING OFF or bin sort result is LO.
+1 ~ +8 BINNING sort result.
+9 Bin sort result is HI.
+10 Bin sort result is OUT.
+11 STBY state
(5) Command: CALCulate:BINNing:MATH:NAME { DEV|PCNT}
Function: It sets or queries the expression of value.
Parameter: DEV indicates the expression is absolute value.
PCNT indicates the expression is percentage value.

Table of Contents