18
No.
Description
Setting
Default
Display conditions
Circuit 1 (CONTINUED)
1
325
Opening of circuit 1 expansion valve
%
If P42 = CIAT and P3 = 1
1
326
Circuit 1 liquid temperature
°C
If P2 = 1 or 2 or (3 + cooling mode)
1
327
Circuit 1 subcooling
°C
If P2 = 1 or 2 or (3 + cooling mode)
1
328
No. of cut-offs caused by C1 electronic
expansion valve fault in 24 hours
If P42 = ALCO
Circuit 2
1
330
Circuit 2 HP
If P3 = 2
1
330.1
Circuit 2 HP control setpoint
If P3 = 2 and Intertwined
1
331
Circuit 2 condensation temperature
See appendix
If P3 = 2
1
332.1
Discharge temperature 3
Discharge temperature 2
°C
If P3 = 2 and P4 = 2
If P3 = 2 and P4 = 1
1
332.2
Discharge temperature 4
°C
If P3 = 2 and P5 = 2
1
333.1
Desuperheat on discharge 3
Desuperheat on discharge 2
P332.1 - P331
If P3 = 2 and P4 = 2
If P3 = 2 and P4 = 1
1
333.2
Desuperheat on discharge 4
P332.2 - P331
If P3 = 2 and P5 = 2
1
334
Circuit 2 LP
If P3 = 2
1
335
Circuit 2 evaporation temperature
See appendix
If P3 = 2
1
336
Circuit 2 suction temperature
°C
If P3 = 2
1
337
Circuit 2 superheat
°C
If P3 = 2
1
338
Number of HP2 cut-offs in 24 hours
If P3 = 2
1
339
Number of LP2 cut-offs in 24 hours
If P3 = 2
1
340
Number of starts, stage 1, circuit 2
If P3 = 2
1
341
Runtime (in hours), stage 1, circuit 2
If P3 = 2
1
342
SCP, stage 1, circuit 2
If P3 = 2
1
343
Number of starts, stage 2, circuit 2
If P3 = 2, P5 = 2
1
344
Runtime (in hours), stage 2, circuit 2
If P3 = 2, P5 = 2
1
345
SCP, stage 2, circuit 2
If P3 = 2, P5 = 2
1
352
No. of water line frost protection cut-offs, circuit 2
If P3 = 2 and P2 4, 5
1
353
No. of refrigerant line frost protection cut-offs, circuit 2
1
354.1
No. of cut-offs caused by discharge 2 in 24 hours
No. of cut-offs caused by discharge 3 in 24 hours
If P3 = 2 and P4 = 1
If P3 = 2 and P4 = 2
1
354.2
No. of cut-offs caused by discharge T° 4 in 24 hours
If P3 = 2 and P5 = 2
1
355
Opening of circuit 2 expansion valve
%
P42 = CIAT and P3 = 2
1
356
Circuit 2 liquid temperature
°C
If [P2 = 1 or 2 or (3 + cooling mode)]
and P3 = 2
1
357
Circuit 2 subcooling
°C
If [P2 = 1 or 2 or (3 + cooling mode)]
and P3 = 2
1
358
No. of cut-offs caused by C1 electronic
expansion valve fault in 24 hours
If P42 = ALCO
INPUTS
1
400
Automatic machine operation control
Open/Closed
1
402
Setpoint 1/Setpoint 2 selection
Open/Closed
If P120 = 2 via On/Off control
1
403
Water flow check
Open/Closed
1
404
Fan fault check
Open/Closed
If P2 1 or 5
1
405
Cooling/Heating input check
Open/Closed
If P119 = Cooling/Heating via On/Off control
1
406
Phase controller
Open/Closed
1
407
Recovery operating mode selection
Open/Closed
If P29 = Yes
1
408
Check of fault input for auxiliary electric heater 1
Open/Closed
If P22 = Yes
1
409
Check of fault input for auxiliary electric heater 2
Open/Closed
If P22 = Yes
1
410
Check of configurable auxiliary electric heater input
Open/Closed
If P22 = Yes
1
414
Check of override/load shedding input 1
Open/Closed
1
415
Check of override/load shedding input 2
Open/Closed
If P4 = 2
1
416
Check of override/load shedding input 3
Open/Closed
If P3 = 2
1
417
Check of override/load shedding input 4
Open/Closed
If P5 = 2

Table of Contents