Microchip and LCD display
electronic regulation and
signaling electronic module
for liquid coolers
and heat pumps
NA 09.13 H
09 - 2011
Installation
Operation
Commissioning
Maintenance

Table of Contents

Questions and Answers

  • А
    АндрейSep 30, 2026
    Ошибка вентилятора не включается чиллер

    Summary

    Important Recommendations

    Electrical power supply

    Rules for connecting electrical power supply to the machine.

    Access Levels

    Selecting an authorised access level

    How to choose the desired access level (User, Technician, CIAT).

    Accessing the various access levels

    Procedures for logging into different access levels using codes.

    List of Parameters

    Setpoint Management

    Parameters for managing cooling and heating setpoints and their adjustments.

    Contents of the Menus

    SETPOINTS menu

    Accessing and modifying control setpoints based on operating mode.

    MACHINE STATUS menu

    Main table

    Displays general machine status, operating modes, and faults.

    MACHINE STATUS table

    Table listing machine status messages and their priority.

    Table of “MACHINE STATUS circuit x fault” messages

    Table listing circuit-specific fault messages and their priority.

    MACHINE PARAMETERS menu

    CONTROLS

    Main control in cooling and heating modes

    Principle of operation for cooling and heating modes, including stage control.

    Water temperature setpoint adjustment

    Adjusting water temperature setpoints based on control mode.

    Adjustment of water temperature setpoint if P7 ≠ INVERTER

    Adjusting setpoints for non-inverter compressors using stage differentials.

    Adjustment of setpoint for the water supply and return temperatures (P141 = 1 or 2) if P7 = INVERTER

    Adjusting setpoints for inverter compressors based on supply/return temps.

    Control setpoint (P251) management

    Management of control setpoints based on winter protection and console/input selection.

    Automated self-regulating control

    Automatic adjustment of control parameters for optimal performance.

    CONTROL OF CONDENSING PRESSURE FOR AIR-COOLED UNITS

    Control during normal operation or on;off control

    Condensing pressure control during normal or on/off operation.

    Fan speed control

    Fan speed control if P7 = INVERTER

    Fan speed control specific to inverter compressors.

    Management of the air blades if P10 = Centrifugal

    MANAGEMENT OF THE AUXILIARY HEATER BOARD AND THE ELECTRIC AUXILIARY HEATERS

    Management of the electrical auxiliary heaters under normal operation

    Operation of electric auxiliary heaters under normal conditions based on temperature.

    MANAGEMENT OF THE BACK-UP BOILER

    Management under normal operation

    Boiler operation under normal conditions based on air temperature.

    MASTER;SLAVEE CONTROL

    Case of two parallel-connected machines

    Setup and configuration for two parallel-connected machines.

    ACTUATION OF THE ELECTRONIC EXPANSION VALVEE

    COMMUNICATION PROTOCOL

    CIAT Connect 2 Specifications

    General IconGeneral
    Power Consumption5 W
    Operating Temperature-10°C to +50°C
    Weight200 g
    Protection ClassIP20
    Input Voltage24 V DC
    Communication InterfaceModbus RTU