2.2. Converter features
MAGNITUDE
VALUE
Power
7.5kVA-200kVA
Input side (GRID side)
AC Voltage
Rated
3x400Vrms+Neutral+Earth
Voltage range
+15% / -20%
Rated AC Current
Depends on model (see table)
10-290Arms per phase
Frequency
48-62Hz
THDi
(at rated power)
<3%
Power Factor
Typical at rated power
≥0.99
Configurable by user
0-1 (capacitive/inductive)
Efficiency
(at rated power)
>92%
Overload
125% for 10 min /150% for 60 s
Output side (EUT side)
DC Voltage
Channel-Com_neg
Channel_Com_neg
Channel_com_neg
20 to 750V (≤60kVA)
40 to 750V (>60kVA)
-350 to 350V
Minimum voltage
At rated power
320V
DC Current
Parallel channels mode
Independent channels mode
Bipolar output
0 to ±555A global
0 to ±185A per channel
0 to ±185A per channel
DC Overcurrent
110% during 1min
Modes of operation
Range
Resolution
Ripple
Constant Current
0-±100%
<±0.1%
<1%
Constant Power
0-±100%
<±0.1%
<1%
Constant Resistance
min.-100%
<±0.1%
<1%
Constant Voltage
0-100%
<±0.1%
<1%
Response time
Rated resistance load
1-5ms (10-90%)
General
Measurements
Input Voltage (Vrms) and current (Irms)
Input and Output Power
Output voltage (Vrms) and current (Irms)
Temperatures
User interface
3.2’’ Touchscreen
Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO)
Communication Port: Ethernet (Optionals: RS485, RS232, CAN)
Communication Protocol: Modbus/TCP
Humidity
10-90% (Absolute maximum, without condensation)
Temperature
5-35ºC (Absolute maximum)
Cooling
Forced air
Protections
Over Current, Over Voltage, Shortcircuit, Overtemperature
Standards
CE Marking
Safety
EN-62040-1-2,EN-60950-1
EMC
EMC: EN-62040-2