EasyManuals Logo

Cisco Firepower 9300 Hardware Installation Guide

Cisco Firepower 9300
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
hot swapping. The power supply entry module is not removable. This is the module that you plug the
power cords into.
After removing power from the chassis either by moving the power switch to OFF or unplugging the
power cord, wait at least 10 seconds before turning power back ON.
Note
Table 6: AC Power Supply LEDs
Amber LEDGreen LEDPower Switch Position
OffOffOnNo input AC power
OffOffOff
On
OffOnPower supply failure
Flashing
Power supply
warning, must be
reset by the system
OffOff
Off
On
Normal operation
OnPower present
OffFlashing (1 Hz)
12-V output disabled
Off
DC Power Supply Module
The power switch controls the DC power output. The system input power is +12 V. If the power switch
is off (standby) when input DC (-48 V) is present, the main power is turned off and only +3.3 V standby
is available for the system. If the power switch position is on (active) when input DC (-48 V) is present,
the main power is turned on as well as +3.3 V standby, and the system is running.
After removing power from the chassis either by moving the power switch to OFF or unplugging the
power cord, wait at least 10 seconds before turning power back ON.
Note
The following table describes the DC power supply LEDs.
Table 7: DC Power Supply Module LEDs
Amber LEDGreen LEDPower Switch PositionInput DC Power -48V
OffOffOnNo input DC power
OffOffOff
Cisco Firepower 9300 Hardware Installation Guide
27
Overview
Power Supply Modules

Other manuals for Cisco Firepower 9300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 9300 and is the answer not in the manual?

Cisco Firepower 9300 Specifications

General IconGeneral
ChassisModular
Security ModulesUp to 3
Firewall ThroughputUp to 1.2 Tbps
ManagementCisco Firepower Management Center
Form FactorRack-mountable
Number of Slots3
Encryption ThroughputUp to 100 Gbps
Operating Temperature32 to 104°F (0 to 40°C)
Humidity10% to 90% non-condensing
AltitudeUp to 10, 000 ft
Power SupplyDual, hot-swappable
Product TypeSecurity Appliance
Supported ModulesSecurity, network, and interface modules
RedundancyYes

Related product manuals