EasyManua.ls Logo

Cisco Nexus 5500 Series - Page 293

Cisco Nexus 5500 Series
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1287
Cisco Nexus 5500 Series NX-OS Layer 2 Interfaces Command Reference
OL-27880-02
Chapter Show Commands
show interface ethernet
Input flow-control is off, output flow-control is off
Switchport monitor is off
EtherType is 0x8100
Last link flapped never
Last clearing of "show interface" counters never
0 interface resets
30 seconds input rate 0 bits/sec, 0 packets/sec
30 seconds output rate 0 bits/sec, 0 packets/sec
Load-Interval #2: 5 minute (300 seconds)
input rate 0 bps, 0 pps; output rate 0 bps, 0 pps
RX
0 unicast packets 0 multicast packets 0 broadcast packets
0 input packets 0 bytes
0 jumbo packets 0 storm suppression bytes
0 runts 0 giants 0 CRC 0 no buffer
0 input error 0 short frame 0 overrun 0 underrun 0 ignored
0 watchdog 0 bad etype drop 0 bad proto drop 0 if down drop
0 input with dribble 0 input discard
0 Rx pause
TX
0 unicast packets 0 multicast packets 0 broadcast packets
0 output packets 0 bytes
0 jumbo packets
0 output errors 0 collision 0 deferred 0 late collision
0 lost carrier 0 no carrier 0 babble 0 output discard
0 Tx pause
switch#
This example shows how to display the counters configured on a specified interface:
switch# show interface ethernet 1/1 counters
--------------------------------------------------------------------------------
Port InOctets InUcastPkts
--------------------------------------------------------------------------------
Eth1/1 0 0
--------------------------------------------------------------------------------
Port InMcastPkts InBcastPkts
--------------------------------------------------------------------------------
Eth1/1 0 0
--------------------------------------------------------------------------------
Port OutOctets OutUcastPkts
--------------------------------------------------------------------------------
Eth1/1 0 0
--------------------------------------------------------------------------------
Port OutMcastPkts OutBcastPkts
--------------------------------------------------------------------------------
Eth1/1 0 0
switch#
This example shows how to display the detailed configuration information of a specified subinterface:
switch# show interface ethernet 1/5.2
Ethernet1/5.2 is up
Hardware: 1000/10000 Ethernet, address: 0005.73a6.1dbc (bia 0005.73a6.1d6c)
Description: Eth 1/5.2 subinterfaces
Internet Address is 192.0.2.3/24
MTU 1500 bytes, BW 1500 Kbit, DLY 2000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation 802.1Q Virtual LAN, Vlan ID 100
EtherType is 0x8100

Other manuals for Cisco Nexus 5500 Series