1288
Cisco Nexus 5500 Series NX-OS Layer 2 Interfaces Command Reference
OL-27880-02
Chapter Show Commands
show interface ethernet
switch#
This example shows how to display the brief configuration information of a specified subinterface:
switch# show interface ethernet 1/5.2 brief
--------------------------------------------------------------------------------
Ethernet VLAN Type Mode Status Reason Speed Port
Interface Ch #
--------------------------------------------------------------------------------
Eth1/5.2 100 eth routed up none 10G(D) --
switch#
This example shows how to display the purpose of a specified subinterface:
switch# show interface ethernet 1/5.2 description
-------------------------------------------------------------------------------
Port Type Speed Description
-------------------------------------------------------------------------------
Eth1/5.2 eth 10G Eth 1/5.2 subinterfaces
switch#
This example shows how to display the switchport information for a specific interface:
switch# show interface ethernet 1/2 switchport
Name: Ethernet1/2
Switchport: Enabled
Switchport Monitor: Not enabled
Operational Mode: trunk
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Trunking VLANs Enabled: 1,300-800
Pruning VLANs Enabled: 2-1001
Administrative private-vlan primary host-association: none
Administrative private-vlan secondary host-association: none
Administrative private-vlan primary mapping: none
Administrative private-vlan secondary mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk private VLANs: none
Operational private-vlan: none
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Monitor destination rate-limit: 1G
switch#
Related Commands Command Description
interface ethernet Configures an Ethernet IEEE 802.3 interface.
interface ethernet
(Layer 3)
Configures a Layer 3 Ethernet IEEE 802.3 interface.
switchport mode vntag Configures an Ethernet interface as a VNTag port.
switchport monitor
rate-limit
Configures the rate limit for traffic on an interface.

Other manuals for Cisco Nexus 5500 Series

Related product manuals