4-20
Cisco ONS 15454 SONET/SDH ML-Series Multilayer Ethernet Card Software Feature and Configuration Guide, R4.0
78-15224-02
Chapter 4 Configuring Interfaces
Common ML-Series POS Configurations
!
router ospf 1
log-adjacency-changes
network 192.168.2.0 0.0.0.255 area 0
network 192.168.3.0 0.0.0.255 area 0
!
Note The default encapsulation for the ML-Series card is LEX and the corresponding default MTU is 1500
bytes. When connecting to an external POS device, it is important to ensure that both the ML-Series
switch and the external device uses the same configuration for the parameters listed in Table 4-4.
ML-Series Card to G-Series Card
Figure 4-4 illustrates a POS configuration between an ML-Series card and a G-Series card.
Figure 4-4 ML-Series Card to G-Series Card POS Configuration
Router_A Configuration
hostname Router_A
!
interface FastEthernet0
ip address 192.168.1.1 255.255.255.0
!
Table 4-4 ML-Series Parameter Configuration for Connection to a Cisco 12000 GSR-Series Router
Command Parameter
Router(config-if)# encapsulation ppp
or
Router(config-if)# encapsulation hdlc
Encapsulation—Default encapsulation is HDLC on
GSR. Default encapsulation on ML-Series card is LEX.
Router(config-if)# show controller pos
C2 Byte—Use the show controller pos command to
verify that the transmit and receive C2 values are the
same.
Router(config-if)# pos flag c2
value
Sets the C2 byte value. Valid choices are 0 to 255
(decimal). The default value is 0x01 (hex) for LEX.
ONS 15454
with ML100T-12
fast ethernet 0
pos 0
ML_Series_A
SONET/SDH
192.168.1.1
192.168.2.1
ONS 15454
with G-Series
Ethernet
83125