B-9
Cisco SCE8000 GBE Installation and Configuration Guide
Appendix B CLI Commands to Verify a Successful Installation
CLI Command Output Samples
show RDR-formatter
Look for:
• Forwarding mode
• Status (in Status column in the Connection Table)
SCE8000> show RDR-formatter
Status: enabled
Connection is: up
Forwarding mode: redundancy
Connection Table:
--------------------------------------------------------------------------------
| Collector | Port |Status| Priority per Category: |
| IP-Address / | | |------------------------------------------------|
| Host-Name | | | Category1 | Category2 | Category3 | Category4 |
|---------------|-------|------|-----------|------------|-----------|-----------|
| 10.240.59.39 | 33000 | up |100 primary| --- | --- | --- |
| 10.240.59.44 | 33000 | up | --- |100 primary | --- | --- |
---------------------------------------------------------------------------------
RDR: queued: 0 ,sent:60108106, thrown: 0, format-mismatch: 0
UM: queued: 0 ,sent: 0, thrown: 0
Logger: queued: 0 ,sent: 0, thrown: 0
Errors: thrown: 0
Last time these counters were cleared: 07:36:52 EDT TUE April 28 2009
show interface linecard subscriber sm-connection-failure
If working with the Subscriber Manager, use this command to make sure the connection with the SM is
established:
SCE8000> show interface linecard 0 subscriber sm-connection-failure
Current SM link state: up.
Configured action to take when SM link is down: No action.
Changing of system operational-status to 'warning' when SM link is down: enabled.