EasyManuals Logo

Cisco SG350-28P Administration Guide

Cisco SG350-28P
762 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #603 background imageLoading...
Page #603 background image
Security: IPv6 First Hop Security
Configuring IPv6 First Hop Security through Web GUI
Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4 462
26
- Inherited—Minimal preference is inherited from either the VLAN or system default
(client).
- No Verification—Disables verification of the minimum advertised preference value
of the packet received.
- User DefinedVerifies that the advertised preference value is greater than or equal
to this value. This value must be less than the Maximal Preference value.
Maximal PreferenceThis field indicates whether the DHCPv6 Guard policy will
check the maximum advertised preference value of the packet received. This value must
be greater than the Minimal Preference value.
- Inherited—Minimal preference is inherited from either the VLAN or system default
(client).
- No Verification—Disables verification of the lower boundary of the hop count limit.
- User DefinedVerifies that the advertised preference value is less than or equal to
this value.
STEP 6 Click Apply to add the settings to the Running Configuration file.
STEP 7 To attach this policy to an interface:
Attach Policy to VLAN—Click to jump to Policy Attachment (VLAN) page where
you can attach this policy to a VLAN.
Attach Policy to Interface—Click to jump to Policy Attachment (Port) page where you
can attach this policy to a port.
ND Inspection Settings
Use the Neighbor Discovery (ND) Inspection Settings page to enable the ND Inspection
feature on a specified group of VLANs and to set the global configuration values for this
feature. If required, a policy can be added or the system-defined default ND Inspection
policies can be configured in this page.
To configure ND Inspection:
STEP 1 Click Security > IPv6 First Hop Security > ND Inspection Settings.
The existing policies are displayed. The fields are displayed below except for the Policy Type
field. This displays whether the policy is user-defined or a default one.

Table of Contents

Other manuals for Cisco SG350-28P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350-28P and is the answer not in the manual?

Cisco SG350-28P Specifications

General IconGeneral
ModelSG350-28P
CategorySwitch
Ports28
PoE Ports24
PoE Budget195W
Switching Capacity56 Gbps
Forwarding Rate41.67 Mpps
LayerLayer 3
Rack MountableYes
Gigabit Ethernet Ports28
MAC Address Table Size16K
Power SupplyInternal
Jumbo Frame SupportYes
Dimensions (W x D x H)440 x 257 x 44 mm
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Humidity10% to 90% non-condensing