D15335.02 Cisco TelePresence MX700 and MX800 API Reference Guide CE8.0, FEBRUARY 2016.
Copyright © 2016 Cisco Systems, Inc. All rights reserved. 150
Cisco TelePresence MX700 and MX800
API Reference Guide
GPIO status
xStatus GPIO Pin [1..4] State
Shows the current state of each GPIO pin. The default state is High (+12V). When activated the
state is Low (0V).
Value space of the result returned:
High/Low
Example:
xStatus GPIO Pin 1 State
*s GPIO Pin 1 State: High
** end
H323 status
xStatus H323
Shows the top level overview of the H323 status.
xStatus H323 Gatekeeper Address
Displays the IP address of the gatekeeper where the system is registered.
Value space of the result returned:
String
Example:
xStatus H323 Gatekeeper Address
*s H323 Gatekeeper Address: "192.0.1.20"
** end
xStatus H323 Gatekeeper Port
Shows the port which is used when connecting to on the gatekeeper.
Value space of the result returned:
Integer
Example:
xStatus H323 Gatekeeper Port
*s H323 Gatekeeper Port: 1719
** end
xStatus H323 Gatekeeper Reason
Shows the reason for rejected registration.
Value space of the result returned:
String
Example:
xStatus H323 Gatekeeper Reason
*s H323 Gatekeeper Reason: ""
** end