Transceiver Specifications
Table 11: General Specifications for the 10-Gigabit Ethernet SFP+ Transceiver Module
Short RangeDescription
LCConnector type
850 nmWavelength
62.5 microns—33 m
50 microns—300 mCore size—Cable distance
Environmental Conditions and Power Requirements Specification for SFP
Transceivers
Table 12: Environmental Conditions and Power Requirements Specifications for SFP Transceivers
MaximumMinimumSymbolParameter
85°C (185°F)-40°C (-40°F)TSStorage temperature
1
70°C (158°F)0°C (32°F)TCCase temperature
2,
95%5%RHRelative humidity
2
3.5 V3.1 VVCCT,RModule supply voltage
2
1
Absolute maximum ratings are those values beyond which damage to the device may occur if these
limits are exceeded for other than a short period of time.
2
Functional performance is not intended, device reliability is not implied, and damage to the device may
occur over an extended period of time between absolute maximum ratings and the recommended
operating conditions.
General Specifications for Cisco Fibre Channel SFP Transceivers
The table below lists the general specifications for Cisco Fibre Channel SFP transceivers at 4 Gbps.
Table 13: General Specifications for Cisco Fibre Channel SFP Transceivers at 4 Gbps
Short WavelengthDescription
LCConnector type
850 nmWavelength
MMFFibre type
62.5 microns—164.04 yd (150 m)
50 microns—328.08 yd (300 m)Core size—Cable distance
Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide
45
Technical Specifications
Transceiver Specifications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS 6454 and is the answer not in the manual?

Cisco UCS 6454 Specifications

General IconGeneral
Product TypeFabric Interconnect
Ports54
USB Ports1 x USB 2.0
Form Factor1 RU
ManagementCisco UCS Manager
Port TypesFCoE, FC
Downlink Ports48 x 10/25 Gbps SFP28
Management Ports1 x 1 Gbps RJ45
Console Ports1 x RJ45
LatencyLess than 1 microsecond
RedundancyRedundant power supplies and fans
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5 to 95% relative humidity, noncondensing
Power Supply650W AC, hot-swappable