ESC x n
[Function] Selecting the time interval for automatically switching Off the printer.
[Code] <1B>H<78>H<n>
[Range] {1 =< n =< 3C(Hex)}
[Outline] Sets the time interval after which the printer will be switched Off automatically if
there is no incoming data through the Serial interface, there is no IrDA communication
and LF button is not pressed. The maximum value for the interval is 60 minutes
<3C>H .
[Default] n = 05(Hex) 5 minutes
[Sample Program]
PRINT #1, CHR$ (&H1B) + “x” + CHR$ (H14);
After executing this command the printer will perform auto power off after 20 minutes,
if there is no IrDA communication and LF button is not pressed.