TIC LINER Hydraulic / Electric System
10/04 4-25
Caution:
Never activate the emergency program directly after setting the basic
values.
When activating the emergency program directly following this setting
process, a malfunction will occur:
When pressing key 9 at the end of the field, all rotors are raised up to the
programmed height; when pressing key 9 (lower rotors to working
position) one more time, the front rotors will not be lowered, but raised up
to their transport position.
Remedy:
Raise and lower the rotors 20 times (using key 9) in normal operating
mode.