Hydraulic / Electric System LINER TIC
4-28 10/04
1.6.3 Adjustment of
angle transmitters
Front angle transmitter The front angle transmitter must be installed at right angles (approx. 90°)
to the frame (see picture).
Rear angle transmitter The rear angle transmitter must be installed parallel to the frame. The
position of the notch (K) in the actuation lever must point towards the
frame or upwards when the rotors are lowered. (see picture).
1.6.4 Checking the signal
voltages
This applies to both angle
transmitters:
Supply voltage: 12 volt
Rotors raised (transport position): Signal voltage above 0.5 volt
Rotors lowered: Signal voltage below 4.5 volt.
Measuring cable
part no. 174 689.0