13.1.7 FIXED TRAVEL SPEED DISPLAY
This machine has the function to travel at the fixed speed in advance.
There are 5 steps, such as 3, 4, 5, 6, 7km/hr, selectable. This function is
displayed by operating Function selection switch. If this function is selected, the
turtle mark is displayed, correspond speed is displayed on letter information
display. Therefore, if travel level is ON after designating fixed speed, the
machine will travel with only fixed speed. This function can limit speed while
the machine is carrying important load, so that the change of travel speed
occurred by improper operation can be minimized.
13.1.8 TROUBLE DISPLAY
It displays the contents of trouble. If a trouble occurs, relevant lamps in all
parts of the machine, such as travel system , hydraulic system , steering
system , are intended to be lightened. If the relevant lamps are lighted up,
stop working and take measures for the trouble before operating the machine.
13.1.9 SAFETY MONITOR
There are safety warning lamps, such as overheat of travel motor , overheat
of travel/hydraulic FET , abrasion of travel motor brush , and
etc. These lamps are lighted with warning description on the letter information
display. When motor overheat lamp and FET overheat lamp are lighted up, the
output of power will be limited. If the machine is kept running continuously after
the lamps are lightyed up, it may cause fatigue to relevant parts. Therefore
stop the machine for 20~30minutes and use the machine after the temperature
goes down.
When brush wear warning lamp is lighted up, check the status of travel
motor and replace it.