TROUBLESHOOTING
Trouble Possible Cause Remedy
The motors do not turn on.
The power supply cable is faulty or disconnected from
the electrical mains.
Replace (*) or connect the cable.
The switch (26) is broken. Replace. (*)
The brush motor does not run.
The push-buttons (51) are broken. Replace. (*)
The switch (52) is broken. Replace. (*)
The vacuum system motor does not
turn on.
The switch (53) is broken. Replace. (*)
The dirty water vacuuming is
insufcient.
The recovery tank is full. Empty.
The vacuum grid is clogged or the oat is closing. Clean the grid and check the oat.
The vacuum hose is disconnected from the squeegee
or faulty.
Connect.
The squeegee is dirty, or the squeegee blades are
worn or damaged.
Clean the squeegee or replace the blades.
The recovery tank cover is not properly closed, or the
gasket is damaged.
Check and/or clean the seating surface or replace
the gasket.
The vacuum system motor lter is dirty. Clean.
The solution ow is insufcient.
The solution lter is dirty. Clean.
The solution solenoid valve is faulty. Replace. (*)
The squeegee leaves marks on the
oor.
There is debris under the squeegee blades. Remove the debris.
The squeegee blades are worn, chipped or torn. Replace the blades.
(*) This maintenance procedure must be performed by an authorised Clarke Service Center.
For further information, refer to the Service Manual, available at any Clarke Service Center.