14 P2552HW | 2021-04 Apex Tool Group
1
EN
Connectors – external power supply
Example:
Inputs
The external 24 V power supply for the controller must
be SELV (Safety Extra Low Voltage) or PELV (Protec-
tive Extra Low Voltage).
Pin 11 and 23 (common GND) serve as a "return line"
for the outputs.
The GND for the external 24 V power supply must be
used as the return line for Pin 11 and 23.
Outputs
The external 24 V power supply for the controller must
be SELV (Safety Extra Low Voltage) or PELV (Protec-
tive Extra Low Voltage).
Pin 2 and 14 (common output) are the voltage source
for the inputs.
Pin 2 and 14 must be connected to the external 24 V
power supply.
6 SD Card
Required for the operation of the controller, the archiving of
data and configurations. Not included with the controller.
7 Items Delivered
Check delivery for transit damage and ensure that all items
have been supplied:
Controller
EC Declaration of Conformity
This Hardware Description
Quick Installation Guide
Warranty
Order no. SWB-S168300 – SD card plus Software
Order no. S981211 – Mating Connector X9/X10 (2×)
Order no. 962405PT – STO plug, bridged
Power Cord V Lock, varies by model:
Signal X9 Signal X10
Pin I/O Name Pin I/O Name
12 Supply GND Int. 24 Supply GND Int.
11 Supply GND I/O 23 Supply GND I/O
10 Output O3 22 Output O3
9 Output O2 21 Output O2
8 Output O1 20 Output O1
7 Output O0 (linking OK), e.g. 19 Output O0 (linking OK), e.g.
6 Input I3 (tool start), e.g. 18 Input I3 (tool start), e.g.
5 Input I2 17 Input I2
4 Input I1 16 Input I1
3 Input I0 15 Input I0
2 Supply +24 V O 14 Supply +24 V O
1 Supply +24 V Int. 13 Supply +24 V Int.
+
-
Note
Only remove or plug in the SD card when
the supply voltage is switched off. Other-
wise, serious system errors and data loss
will result.
Order no. 962276PT mPro300GCD-STO-EMEA
Order no. 962278PT mPro300GCD-STONA 115 VAC
•–
(see Accessories)
mPro300GCD-STOAPC