EasyManua.ls Logo

Cleco mPro300GCD-STO - Product Description; Product Power Supply; Product Safety Technology; Technical Specifications

Cleco mPro300GCD-STO
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 P2552HW | 2021-04 Apex Tool Group
1
EN
3 Product description
Controller for use in safety-critical tightening.
The controller is primarily used as a control and monitoring
unit for one or more tools at a workstation. Depending on
the peripheral devices that are procured, the controller can
also be installed outside of the work environment.
Software is already installed on the controller. The tighten-
ing settings must be carried out by a qualified person using
the controller or remote PC software (mProRemote) in
order to start fastening work. For further information
regarding software operation, please reference the Pro-
gramming Manual.
Nutrunner controllers with the suffix STO in the type name
are equipped with the STO safety function, see Chapter 9
STO safety function, Page 16.
4 Technical Specifications
Ambient Conditions
Power Supply
Safety Technology
Normative references
For product-relevant EC Directives, as well as the stan-
dards complied with, see the EC Declaration of Conformity.
Features Data
Operation Site Indoors
Ambient Temperature 0...45 °C
1
1 Note the derating. See System Handbook NeoTek™
Storage Temperature -20...70 °C
Type of Cooling Convection (self-cooling)
Relative Humidity 10...90 %
No Condensation
Working Height Up to 3000 m
Above Sea Level
1
Protection Class
DIN EN 60529
IP42
Protection Class
DIN EN61140
(VDE 0140-1)
I
Degree of Contamination
EN 61010
2
Transient Overvoltage
EN 61010
CAT

Maximum Shock
DIN EN 60068-2-27
15 G
Maximum Vibration
DIN EN 60068-2-5
59.6–160 Hz: 2 G
Features Data
Supply Voltage,
Single Phase
100–240 VAC ± 10%
1
1 When operating outside the allowable voltage limits,
the integrated power supply enters a protection mode
and switches off. This protection mode can be reset
by restarting the nutrunner controller.
Rated Supply Current 2–1 A
Frequency 50/60 Hz
Peak Current 16 A
Rated Power 1600 VA max.
Idling 40 VA
Safety indices
Safety
function
STO Safe start lockout (STO, Safe
Torque Off) in accordance with
EN 61800-5-2, with SIL 2
Safe start lockout (STO, Safe
Torque Off) in accordance with
EN ISO 13849-1, Category 3 and
PL d
SIL SIL 2 Safety level (Safety Integrity
Level) in accordance with EN
61800-5-2
Category 3 Classification in the category is in
accordance with EN ISO 13849-1
PL PL d Performance Level is in accor-
dance with EN ISO 13849-1
DCavg 60% Low, average diagnostic cover-
age (Average Diagnostic Cover-
age)
HFT 1 Hardware Failure Tolerance
SFF > 60% Safe Failure Fraction
PFH 9.1 E-10 1/h < 0.1% of SIL 2, Probability of
dangerous Failure per Hour
PFDav
(T = 20 a)
7.9 E-05 0.8% of SIL 2, Probability of dan-
gerous Failure on Demand
T
PTI
[months]
12 Proof Test Interval service life in
accordance with EN ISO 13849-1
MTTFd > 2.000 a HIGH, Mean time to dangerous
failure

Related product manuals