ClimaCool UCW 30 - Options and Accessories; Automatic CS Series Strainer Package; Heat Pump; Heat Recovery

ClimaCool UCW 30
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
®
www.climacoolcorp.com
42
Automatic CS Series Strainer Package
Field installed, high quality, low maintenance stainless steel

will reduce operating costs and prevent nuisance condenser
issues. Strainer package can be equipped with optional

Heat Pump
Factory installed reverse cycle heating and cooling operation
compatible with boiler/tower or geothermal systems.
Heat Recovery
Factory installed option providing hot water, as high as
140°F, while simultaneously producing chilled water for the
chiller system.
Hot Gas Bypass
Factory installed on both circuits allowing unit operation
below the minimum step of unloading.
Manual Strainers
Field installed strainers utilize Y-style and Basket strainers
of cast iron 200 psi or carbon 275 psi with 60 mesh stainless


chiller bank for ease of service.
Motorized or Manual Water Isolation Valves
and Flush Ports

shall provide isolation to the module for maintenance and
cleaning of evaporator and condenser heat exchangers
while adjacent modules continue normal operation. Both

Note: All Heat Pump congurations require
motorized valves.
Motorized condenser water valves provide head pressure
regulation for low entering condenser water temperature

Available choices include:
One each motorized valve for evaporator and
condenser with one each manual valves for the
evaporator and condenser.
One each motorized valve for the evaporator and one
each manual valve for the evaporator and two each
manual valves for the condenser.
Two each manual valves for the evaporator and
the condenser.
Pressure Dierential Flow Sensor
Field installed to prevent operation of chiller without

Seismic Certication
Factory installed seismic tested in accordance with OSHPD
standars for cooling only chillers.
Water Header Bypass
Field installed water header bypass may be utilized to
prevent deadheading the pump. A bypass is mandatory with
all motorized valve applications.
Options available for following:
Direct Return:
Motorized evaporator/condenser water
isolation valves
Motorized evaporator/manual condenser water
isolation valves
Reverse Return:
Motorized evaporator/condenser water
isolation valves
Motorized evaporator/manual condenser water
isolation valves
Options and Accessories