MAN.241 Rev.5 ENG - Use and maintenance manual S23 page 70 of 127
The more you clean the MEWP, the more you
have to lubricate it.
Cleaning the electrical/electronic parts with
water is prohibited. Failure to comply with this
requirement can cause serious damage to the
system electric machine.
To clean electrical parts, use only dry clean-
ers.
• Dry the machine thoroughly before turning it
on again (for example with compressed air).
• Make sure that moisture has not entered the
electrical engine or other parts of the electrical
system.
4.9.3 Prevention against electric light-
ning stroke
If you need to work with the machine near power
lines, the user is obliged to keep an adequate dis-
tance.
Below there are the minimum safety distances to be
kept by qualified staff according to their type of volt-
age:
It is forbidden, in any case, to touch live
electrical conductors.
4.9.4 Noise and vibrations
The manufacturer declares that the aerial platforms
have been tested according to the parameters of the
European standard 2000/14/CE, indicating a guaran-
teed sound power level shown on the CE Declaration
of Conformity of the machine. During the phases of
use of the machine for aerial operations, this value is